Phoenix GT

Keep Legionella and Other Waterborne Pathogens Out of Your Building!

Legionella and a host of other pathogens like Pseudomonas and Mycobacterium can survive and thrive in a layer of biofilm in your facility’s piping system. Every year they cause countless infections of the lungs, skin, internal organs, and more. Legionnaire’s disease is of particular concern – especially in healthcare and hotel facilities. A recent memo from the Centers for Medicare and Medicaid Services now mandates infection control programs for health care facility water systems.

Most current control measures involve applying high water temperatures, heavy metals, or harsh/corrosive chemicals to building water systems, in order to bring bacterial levels down below “acceptable” levels. In some situations (particularly in existing facilities with ongoing bacterial problems), these control measures remain essential.

Water Control is excited to bring a significant new tool to the table in the battle against waterborne pathogens: Whole-building (point-of-entry) High-Capacity Ultrafiltration, featuring high-flow, low pressure loss, self-cleaning, hollow fiber membranes by German innovators, Seccua GmbH. These filters screen out 99.999% of all bacteria and particulates (including 99.99% of viruses) before they can ever enter a facility; And they do so without removing essential disinfectants provided by the city.

The results are dramatic. In new facilities, virtually all microorganisms and nutrients are removed before they can gain a foothold in building plumbing systems. Existing chemical residuals from the city are normally more than adequate to keep any organisms (which enter via other means) under control. The self-cleaning membranes last 5 – 10 years before they need changing, and the systems feature automatic membrane integrity monitoring to let operators know when maintenance is required.

In existing facilities, point-of-entry High-Capacity Ultrafiltration becomes an instant “firewall” to virtually any new microorganisms or nutrients entering the facility. The biological life cycle is disrupted. Over a period of several months (typical), and often in conjunction with chemical disinfectant injection and system flushing, pathogen levels drop to undetectable levels. This occurs via a massive “die-off” within the system as microorganisms are starved for nutrients. Note that this process needs to be managed by a qualified infection control professional.

Water Control offers point-of-entry High-Capacity Ultrafiltration systems capable of filtering 700GPM+, with very little pressure loss. These systems feature membrane integrity monitoring, BAS connectablity, variable speed chemical injector control capability, and more.

Need help with a whole-building Legionella and pathogen control application?

Click the Rep Locator in the side bar to locate a local Water Control representative.

High-Capacity Ultrafiltration – Legionella & Pathogen Control Brochure

High-Capacity Ultrafiltration Engineering Guide

Seccua Case Study

Contact Water Control

System Brochures